No, if you consider the cost per unit of heat actually delivered: a boiler has an average real efficiency of about 70% (including distribution and thermoregulation losses), whereas a system like e-Membrane® converts almost 100% of the electricity into heat, without combustion or distribution losses.
With CALDO SYSTEM's D.E.R. logic paired with solar PV, the E.T.E. (Equivalent Thermal Efficiency) increases from 1.8 without PV to 3.0 with PV in insulated buildings. Savings depend on the system's ability to maximise self-consumption of the energy produced.
Although heat pumps are generally more efficient than traditional electric heating, the integration of CALDO SYSTEM bridges this gap. In well-insulated properties equipped with solar PV, our D.E.R. Logic optimises self-consumption, making operating costs comparable to those of a heat pump while eliminating the need for routine and extraordinary maintenance.
A solar PV system without dynamic management loses much of the energy produced to the grid, as domestic production and consumption rarely coincide. CALDO SYSTEM's D.E.R. logic solves this by shifting heating demand to hours of peak solar production.
Not necessarily. The building's thermal mass, charged by D.E.R. logic via e-Membrane® elements, acts as a free thermal store, often proving more cost-effective than an electrochemical battery for the same self-consumption goals.
Savings are measured using E.T.E. (Equivalent Thermal Efficiency), CALDO SYSTEM's proprietary parameter. The value is 1.8 in insulated buildings without solar PV and 3.0 in well-insulated buildings with solar PV, based on real data from over 800 installations monitored since 2014.
Yes. The e-Control unit, through D.E.R. logic, dynamically regulates energy release based on real-time demand zone by zone. It adapts to minor changes in every room, in addition to the scheduled programming set by the user via the CALDO SYSTEM app.
Measured values are extremely low: 0.24 V/m for the electric field and 0.035 microtesla for the magnetic field. These are certified by an Accredia-accredited body in collaboration with the Technical Physics Laboratory of the IUAV University of Venice, well within the limits set by the Italian Prime Ministerial Decree of 8 July 2003.
Yes: e-Membrane® has an IPX7 protection rating, which certifies its resistance to temporary immersion in water, an important requirement for environments such as bathrooms.
This depends on the floor build-up: for renovations, the floating or adhesive e-Membrane® Floor solutions require approximately 27 mm in total; in new builds, the e-Membrane® Floor screed build-up generally requires more (around 50 mm), while the e-Membrane® Wall vertical solution is useful when even 27 mm of floor space is unavailable.
Flooring remains the reference configuration for the most uniform heat distribution, but e-Membrane® Wall still offers superior radiant comfort compared to a traditional radiator, with the added benefit of a faster response time due to lower thermal inertia.
Yes, e-Membrane® Floor and Wall can coexist in the same building or even the same room, all managed centrally by the e-Control unit. In bathrooms, it is common to install both floor radiant elements for primary heating and wall elements to act as invisible towel warmers.
Yes. e-Membrane® Wall applied behind the bathroom finish can function as an invisible radiator, warming towels and bathrobes without any visible heating elements.
The two floor solutions designed by CALDO SYSTEM for renovations—floating and adhesive—both require only 27 mm in total, an identical thickness to ensure continuity between the two build-ups within the same room.
Yes, both with the screed build-up, where there is total freedom of choice for the finish, and with the adhesive build-up where e-Membrane® Floor is bonded with a fibreglass mesh, over which the ceramic (10 mm) and adhesive (2 mm) are laid, for a total of 27 mm.
Yes. When e-Membrane® Wall is installed within an insulating plasterboard partition on perimeter walls, the work improves the building's insulation while providing heating. A single project results in a better-insulated and more comfortable home.
Certainly: CALDO SYSTEM provides extremely precise operating cost forecasts based on actual consumption, calculated from data collected from over 800 installations monitored since 2014, rather than theoretical laboratory estimates.
In new builds, where there are no thickness constraints, the screed layer with e-Membrane® Floor is generally the reference solution. It creates the thermal flywheel that best suits solar PV self-consumption managed by D.E.R. logic, and the comfort of floor heating is superior to that of wall heating.
When designing a new home, the building envelope, the e-Membrane® system, and the photovoltaic system should be sized together from the outset so that the D.E.R. logic can manage self-consumption to its full potential. Typically, the photovoltaic system should cover at least 60% of the installed radiant power.
This is the maximum temperature that can be set for each zone in the CALDO SYSTEM app. The e-Control unit can boost the room up to this limit when it detects available photovoltaic production, turning it into a free thermal store (displayed in the app as “free energy set” with a rocket icon).
Yes. When photovoltaic power is available, e-Control logic transforms the domestic hot water storage cylinder into a true thermal battery, further increasing the self-consumption of the energy produced.
In Automatic mode, the control unit follows the time slots set by the user with temperatures customised room by room. In Manual mode, one or more rooms are locked to a fixed temperature (comfort, economy, or frost protection), regardless of the schedule.
Yes, on several fronts: e-Membrane® contains no refrigerants or mechanical parts subject to wear, is manufactured using cold-working processes 100% in Italy, and, thanks to the absence of mechanical inertia, can switch on and off dynamically following the photovoltaic curve in a way that a heat pump cannot replicate without compromising the compressor. Furthermore, CALDO SYSTEM does not require a heat generator that must be replaced over time.
As there are no mechanical parts or a generator to replace, the e-Membrane® system avoids the maintenance and component replacement (burners, heat exchangers, compressors with refrigerant) typical of boilers and heat pumps over time, reducing the overall impact related to maintenance and the end-of-life of the system. The total lifespan easily exceeds 50 years.
In CALDO SYSTEM Maxi, photovoltaics, heating, cooling, and DHW are connected to a single communal meter. The home automation supervision system analyses and allocates the consumption of these three sectors for each individual apartment.
Yes. In CALDO SYSTEM Maxi, the electric radiant heating is installed individually in each apartment (not centralised), while only the photovoltaic production, VRV cooling, and DHW remain centralised at the building level.
It indicates that a zone is actively promoting the self-consumption of photovoltaic energy thanks to Tmax, meaning the e-Control unit is heating that room using free energy available at that moment.
Both versions offer full control of the system. Only the Pro version retains data history, providing access to the Statistics and Reports sections with their respective consumption and production charts.
Yes, via the timers in the CALDO SYSTEM app: a system can have up to 8 timers controlling up to 24 zones, with the temperature for each mode set independently for every room.
Yes: according to Article 1118, paragraph 4, of the Italian Civil Code and established case law (most recently Cass. 6490/2026), a prohibition on disconnection contained in condominium regulations is void.
Only the costs for extraordinary maintenance and the preservation/compliance of the central system; you no longer pay for routine management or fuel consumption.
No, it is an individual right of the resident. However, prior notification to the building manager is required, accompanied by a technical report.
Often, no. Many apartments in blocks have most sides bordering other heated rooms, meaning heat loss is naturally contained. It is precisely in these cases that CALDO SYSTEM delivers the greatest benefits in terms of consumption.
Because the flow and return circuit inside the radiant tape is made with two overlapping flat strips, rather than round-section cables. The two generated magnetic fields are equal and opposite, cancelling each other out almost perfectly due to their physical proximity.
It is a shield that discharges the electric field to earth. In e-Membrane®, one of the outermost layers forms an aluminium shell connected to earth, which functions exactly in this way, bringing the electric field to very low values.
Yes. It is a certification issued by an Accredia body in collaboration with the technical physics laboratory of the IUAV University of Venice, and is therefore verified by independent third parties.
For those installing an electric radiant heating system, internal wall insulation works particularly well with CALDO SYSTEM, as it decouples the wall's thermal mass from the interior environment, reducing its inertia—an advantage in terms of system responsiveness.
By using breathable materials such as wood fibre or calcium silicate, or by using a continuous vapour barrier on the warm side if EPS or XPS is used. In any case, this must always be verified with a hygrothermal calculation (Glaser method) conducted by a qualified technician.
This depends on the climate zone and the materials selected; a practical target for most of Italy is to achieve thermal transmittance values of approximately 0.25–0.30 W/m²K, though this should always be verified on a case-by-case basis by a qualified technician.
A radiant system such as e-Membrane® Floor typically qualifies for the 'Bonus Ristrutturazioni' (Renovation Bonus) when it is part of a larger extraordinary maintenance project; any associated floor insulation may, however, be eligible for the Ecobonus separately.
Yes: the e-Control unit, with the CALDO SYSTEM app, meets the required criteria (visible consumption, temperature regulation, remote control, Class B of the EN 15232 standard), as attested by the BACS declaration issued by the manufacturer.
The Building Automation Bonus provides a maximum deduction of €15,000 per property unit, with a rate of 50% for primary residences and 36% for other properties in 2026.
This is not the standard channel: the Conto Termico 3.0 is primarily designed for heat pumps, whereas an electric resistance system like e-Membrane® typically falls under the Renovation Bonus and, for the control unit, the Building Automation Bonus.